Remote management
Condition monitoring
Remote operation and maintenance
Safety Control
|
Model |
C5 |
|
|
CPU |
CPU |
Intel® Alder Lake N95 Processor |
|
Max Turbo Frequency |
3.4 GHz |
|
|
Cache |
6MB |
|
|
Cores / Threads |
4/4 |
|
|
Chipset |
SOC |
|
|
BIOS |
AMI UEFI BIOS |
|
|
Memory |
Socket |
1 × DDR4 SO-DIMM slot, 3200 MT/s |
|
Maximum Capacity |
16GB |
|
|
Display |
Graphics |
Intel® UHD Graphics |
|
Network |
Network Controller |
2 / 4 × Intel® i210-AT network controllers (10/100/1000 Mbps) [1] |
|
Storage |
M.2 |
1 × M.2 Key-M slot (SATA 3.0 signal, supports SATA SSD, 2280) |
|
Expansion |
Mini PCIe |
1 × Mini PCIe slot (PCIe x1 + USB 2.0 signals) |
|
Serial Port |
2 × COM ports (COM1 / COM2, DB9 male, optional) [2] |
|
|
External I/O |
USB |
2 * USB 5Gbps(Type-A) |
|
Ethernet |
2 / 4 × RJ45 ports [1] |
|
|
Display |
1 × HDMI port (maximum resolution up to 4096 × 2160 @ 30 Hz) |
|
|
Audio |
1 × 3.5 mm 2-in-1 audio jack (Line-Out + MIC, CTIA standard) |
|
|
Buttons |
1 × Power button |
|
|
Power Supply |
Type |
DC |
|
Input Voltage |
24V |
|
|
Connector |
1 × 3-pin power input connector (P = 5.08 mm) |
|
|
RTC Battery |
CR2032 coin-cell battery |
|
|
OS Support |
Windows |
Windows 10/11 |
|
Linux |
Linux (kernel 5.18 or later) |
|
|
Watchdog |
Output |
System reboot |
|
Interval |
1–255 seconds, programmable |
|
|
Mechanical |
Chassis Material |
Heatsink: Aluminum alloy |
|
Dimensions |
150.7mm(L)*114.5mm(W)*45mm(H) |
|
|
Mounting |
Wall-mount, DIN-rail, desktop |
|
|
Environment |
Cooling System |
Fanless passive cooling |
|
Operating Temperature |
0 to 60 °C (with industrial SSD) |
|
|
Storage Temperature |
-40 to 80 °C (with industrial SSD) |
|
|
Humidity |
5 to 90% RH (non-condensing) |
|
|
Vibration |
IEC 60068-2-64 (3 Grms @ 5–500 Hz, random, 1 hr/axis, with SSD) |
|
|
Shock |
IEC 60068-2-27 (30 G, half-sine, 11 ms, with SSD) |
|
Notes:
[1] Optional configuration with 2 or 4 Ethernet ports.
[2] Signals provided by the motherboard and routed via DB9 knock-out holes; COM1 supports RS-232 / RS-485, COM2 supports RS-232. Optional configuration.